Rocket TRUfusion Enterprise through 7.10.4.0 uses a reverse proxy to handle incoming connections. However, the proxy is misconfigured in a way that allows specifying absolute URLs in the HTTP request line, causing the proxy to load the given resource.
Rocket TRUfusion Enterprise through 7.10.5 exposes the endpoint at /axis2/services/WsPortalV6UpDwAxis2Impl to authenticated users to be able to upload files. However, the application doesn't properly sanitize the jobDirectory parameter, which allows path traversal sequences to be included. This allows writing files to arbitrary local filesystem locations and may subsequently lead to remote code execution.