A time-of-create-to-time-of-use (TOCTOU) vulnerability lets recently deleted-then-recreated data sources be re-deleted without permission to do so.
This requires several very stringent conditions to be met:
- The attacker must have admin access to the specific datasource prior to its first deletion.
- Upon deletion, all steps within the attack must happen within the next 30 seconds and on the same pod of Grafana.
- The attacker must delete the datasource, then someone must recreate it.
- The new datasource must not have the attacker as an admin.
- The new datasource must have the same UID as the prior datasource. These are randomised by default.
- The datasource can now be re-deleted by the attacker.
- Once 30 seconds are up, the attack is spent and cannot be repeated.
- No datasource with any other UID can be attacked.
Public dashboards with annotations enabled did not limit their annotation timerange to the locked timerange of the public dashboard. This means one could read the entire history of annotations visible on the specific dashboard, even those outside the locked timerange.
This did not leak any annotations that would not otherwise be visible on the public dashboard.
SCIM provisioning was introduced in Grafana Enterprise and Grafana Cloud in April to improve how organizations manage users and teams in Grafana by introducing automated user lifecycle management.
In Grafana versions 12.x where SCIM provisioning is enabled and configured, a vulnerability in user identity handling allows a malicious or compromised SCIM client to provision a user with a numeric externalId, which in turn could allow to override internal user IDs and lead to impersonation or privilege escalation.
This vulnerability applies only if all of the following conditions are met:
- `enableSCIM` feature flag set to true
- `user_sync_enabled` config option in the `[auth.scim]` block set to true