Use of weak credentials exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product.
Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.
Missing authentication for critical function exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to execute some critical functions without authentication, e.g., rebooting the product.
Cleartext storage of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote authenticated attacker to obtain an APN credential for the product.
Cleartext transmission of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier. If the telnet connection is enabled, a remote unauthenticated attacker may eavesdrop on or alter the administrator's communication to the product.
Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product's ADB port.
Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.
Improper privilege management vulnerability in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier allows a remote authenticated attacker to alter a WebUI password of the product.
Seiko SkyBridge MB-A100/A110 v4.2.0 and below was discovered to contain a command injection vulnerability via the ipAddress parameter at 07system08execute_ping_01.