Vulnerabilities
Vulnerable Software
Honeywell:  Security Vulnerabilities
The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.
CVSS Score
10.0
EPSS Score
0.002
Published
2026-03-12
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
CVSS Score
9.9
EPSS Score
0.008
Published
2025-05-02
A cross-site scripting (XSS) vulnerability in the component /test/ of iq3xcite v2.31 to v3.05 allows attackers to execute arbitrary web scripts or HTML via a crafted payload.
CVSS Score
6.1
EPSS Score
0.002
Published
2024-09-27
LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements.
CVSS Score
8.8
EPSS Score
0.001
Published
2024-05-30
LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions.
CVSS Score
9.3
EPSS Score
0.009
Published
2024-05-30
LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands.
CVSS Score
9.3
EPSS Score
0.011
Published
2024-05-30
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18644.
CVSS Score
5.5
EPSS Score
0.001
Published
2024-05-03
Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18412.
CVSS Score
7.8
EPSS Score
0.025
Published
2024-05-03
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18456.
CVSS Score
5.5
EPSS Score
0.001
Published
2024-05-03
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of xml files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18563.
CVSS Score
5.5
EPSS Score
0.001
Published
2024-05-03


Contact Us

Shodan ® - All rights reserved