A Remote Code Execution (RCE) vulnerability in the WebUI component of the eQ-3 HomeMatic CCU2 firmware up to and including version 2.57.5 and CCU3 firmware up to and including version 3.57.5 allows remote unauthenticated attackers to execute system commands as root via a simple HTTP request.
eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset).
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the Script Parser AddOn through 1.8 installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi script, which executes TCL script content from an HTTP POST request.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.
A Remote Code Execution (RCE) issue in the addon CUx-Daemon 1.11a of the eQ-3 Homematic CCU-Firmware 2.35.16 until 2.45.6 allows remote authenticated attackers to execute system commands as root remotely via a simple HTTP request.
A Local File Inclusion (LFI) issue in the addon CUx-Daemon 1.11a of the eQ-3 Homematic CCU-Firmware 2.35.16 until 2.45.6 allows remote authenticated attackers to read sensitive files via a simple HTTP Request.
eQ-3 HomeMatic CCU3 firmware 3.41.11 allows session fixation. An attacker can create session IDs and send them to the victim. After the victim logs in to the session, the attacker can use that session. The attacker could create SSH logins after a valid session and easily compromise the system.
eQ-3 HomeMatic CCU3 firmware version 3.41.11 allows Remote Code Execution in the ReGa.runScript method. An authenticated attacker can easily execute code and compromise the system.
eQ-3 Homematic CCU2 before 2.47.18 and CCU3 before 3.47.18 allow Remote Code Execution by unauthenticated attackers with access to the web interface via an HTTP POST request to certain URLs related to the ReGa core process.