Vulnerabilities
Vulnerable Software
7t:  Security Vulnerabilities
Untrusted search path vulnerability in 7-Technologies (7T) TERMIS 2.10 and earlier allows local users to gain privileges via a Trojan horse DLL in the current working directory, a different vulnerability than CVE-2012-0224.
CVSS Score
9.3
EPSS Score
0.006
Published
2012-02-22
Untrusted search path vulnerability in 7-Technologies (7T) AQUIS 1.5 and earlier allows local users to gain privileges via a Trojan horse DLL in the current working directory, a different vulnerability than CVE-2012-0223.
CVSS Score
9.3
EPSS Score
0.006
Published
2012-02-21
Untrusted search path vulnerability in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) before 9.0.0.11291 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
CVSS Score
9.3
EPSS Score
0.006
Published
2012-01-19
Buffer overflow in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) 9.0.0.11200 allows remote attackers to cause a denial of service via a crafted packet to TCP port 12401.
CVSS Score
5.0
EPSS Score
0.754
Published
2011-12-27
Multiple buffer overflows in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) 9.0.0.11355 and earlier allow remote attackers to execute arbitrary code or cause a denial of service via a crafted packet to TCP port (1) 12397 or (2) 12399.
CVSS Score
7.5
EPSS Score
0.032
Published
2011-12-27
Cross-site scripting (XSS) vulnerability in the Admin Control Center in Sentinel HASP Run-time Environment 5.95 and earlier in SafeNet Sentinel HASP (formerly Aladdin HASP SRM) run-time installer before 6.x and SDK before 5.11, as used in 7 Technologies (7T) IGSS 7 and other products, when Firefox 2.0 is used, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors that trigger write access to a configuration file.
CVSS Score
4.3
EPSS Score
0.009
Published
2011-12-17
Stack-based buffer overflow in the Open Database Connectivity (ODBC) service (Odbcixv9se.exe) in 7-Technologies Interactive Graphical SCADA System (IGSS) 9 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet to TCP port 22202.
CVSS Score
10.0
EPSS Score
0.023
Published
2011-07-29
Unspecified vulnerability in the Open Database Connectivity (ODBC) component in 7T Interactive Graphical SCADA System (IGSS) before 9.0.0.11143 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 20222, which triggers memory corruption related to an "invalid structure being used."
CVSS Score
10.0
EPSS Score
0.162
Published
2011-05-31
Directory traversal vulnerability in dc.exe 9.00.00.11059 and earlier in 7-Technologies Interactive Graphical SCADA System (IGSS) allows remote attackers to execute arbitrary programs via ..\ (dot dot backslash) sequences in opcodes (1) 0xa and (2) 0x17 to TCP port 12397.
CVSS Score
10.0
EPSS Score
0.777
Published
2011-04-05
Multiple stack-based buffer overflows in IGSSdataServer.exe 9.00.00.11063 and earlier in 7-Technologies Interactive Graphical SCADA System (IGSS) allow remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via crafted (1) ListAll, (2) Write File, (3) ReadFile, (4) Delete, (5) RenameFile, and (6) FileInfo commands in an 0xd opcode; (7) the Add, (8) ReadFile, (9) Write File, (10) Rename, (11) Delete, and (12) Add commands in an RMS report templates (0x7) opcode; and (13) 0x4 command in an STDREP request (0x8) opcode to TCP port 12401.
CVSS Score
10.0
EPSS Score
0.801
Published
2011-04-05