A Missing Release of Memory after Effective Lifetime vulnerability in the rtlogd process of Juniper Networks Junos OS on MX Series with SPC3 allows an unauthenticated, adjacent attacker to trigger internal events cause ( which can be done by repeated port flaps) to cause a slow memory leak, ultimately leading to a Denial of Service (DoS).
Memory can only be recovered by manually restarting rtlogd process.
The memory usage can be monitored using the below command.
????user@host> show system processes extensive | match rtlog
This issue affects Junos OS on MX Series with SPC3 line card:
* from 21.2R3 before 21.2R3-S8,
* from 21.4R2 before 21.4R3-S6,
* from 22.1 before 22.1R3-S5,
* from 22.2 before 22.2R3-S3,
* from 22.3 before 22.3R3-S2,
* from 22.4 before 22.4R3-S1,
* from 23.2 before 23.2R2,
* from 23.4 before 23.4R2.
A Missing Release of Memory after Effective Lifetime vulnerability in Juniper Networks Junos OS on MX Series allows an unauthenticated adjacent attacker to cause a Denial-of-Service (DoS).
In a subscriber management scenario continuous subscriber logins will trigger a memory leak and eventually lead to an FPC crash and restart.
This issue affects Junos OS on MX Series:
* All version before 21.2R3-S6,
* 21.4 versions before 21.4R3-S6,
* 22.1 versions before 22.1R3-S5,
* 22.2 versions before 22.2R3-S3,
* 22.3 versions before 22.3R3-S2,
* 22.4 versions before 22.4R3,
* 23.2 versions before 23.2R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (pfe) of Juniper Networks Junos OS on SRX Series, and MX Series with SPC3 allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS).
When an affected device receives specific valid TCP traffic, the pfe crashes and restarts leading to a momentary but complete service outage.
This issue affects Junos OS:
21.2 releases from 21.2R3-S5 before 21.2R3-S6.
This issue does not affect earlier or later releases.
A Heap-based Buffer Overflow vulnerability in the telemetry sensor process (sensord) of Juniper Networks Junos OS on MX240, MX480, MX960 platforms using MPC10E causes a steady increase in memory utilization, ultimately leading to a Denial of Service (DoS).
When the device is subscribed to a specific subscription on Junos Telemetry Interface, a slow memory leak occurs and eventually all resources are consumed and the device becomes unresponsive. A manual reboot of the Line Card will be required to restore the device to its normal functioning.
This issue is only seen when telemetry subscription is active.
The Heap memory utilization can be monitored using the following command:
> show system processes extensive
The following command can be used to monitor the memory utilization of the specific sensor
> show system info | match sensord
PID NAME MEMORY PEAK MEMORY %CPU THREAD-COUNT CORE-AFFINITY UPTIME
1986 sensord 877.57MB 877.57MB 2 4 0,2-15 7-21:41:32
This issue affects Junos OS:
* from 21.2R3-S5 before 21.2R3-S7,
* from 21.4R3-S4 before 21.4R3-S6,
* from 22.2R3 before 22.2R3-S4,
* from 22.3R2 before 22.3R3-S2,
* from 22.4R1 before 22.4R3,
* from 23.2R1 before 23.2R2.
A Use After Free vulnerability in command processing of Juniper Networks Junos OS on MX Series allows a local, authenticated attacker to cause the broadband edge service manager daemon (bbe-smgd) to crash upon execution of specific CLI commands, creating a Denial of Service (DoS) condition. The process crashes and restarts automatically.
When specific CLI commands are executed, the bbe-smgd daemon attempts to write into an area of memory (mgd socket) that was already closed, causing the process to crash. This process manages and controls the configuration of broadband subscriber sessions and services. While the process is unavailable, additional subscribers will not be able to connect to the device, causing a temporary Denial of Service condition.
This issue only occurs if Graceful Routing Engine Switchover (GRES) and Subscriber Management are enabled.
This issue affects Junos OS:
* All versions before 20.4R3-S5,
* from 21.1 before 21.1R3-S4,
* from 21.2 before 21.2R3-S3,
* from 21.3 before 21.3R3-S5,
* from 21.4 before 21.4R3-S5,
* from 22.1 before 22.1R3,
* from 22.2 before 22.2R3,
* from 22.3 before 22.3R2;
A Missing Authentication for Critical Function vulnerability in the Packet Forwarding Engine (pfe) of Juniper Networks Junos OS on MX Series with SPC3, and SRX Series allows an unauthenticated network-based attacker to cause limited impact to the integrity or availability of the device.
If a device is configured with IPsec authentication algorithm hmac-sha-384 or hmac-sha-512, tunnels are established normally but for traffic traversing the tunnel no authentication information is sent with the encrypted data on egress, and no authentication information is expected on ingress. So if the peer is an unaffected device transit traffic is going to fail in both directions. If the peer is an also affected device transit traffic works, but without authentication, and configuration and CLI operational commands indicate authentication is performed.
This issue affects Junos OS:
* All versions before 20.4R3-S7,
* 21.1 versions before 21.1R3,
* 21.2 versions before 21.2R2-S1, 21.2R3,
* 21.3 versions before 21.3R1-S2, 21.3R2.
A Missing Release of Memory after Effective Lifetime vulnerability in the IKE daemon (iked) of Juniper Networks Junos OS on MX Series with SPC3, and SRX Series allows an administratively adjacent attacker which is able to successfully establish IPsec tunnels to cause a Denial of Service (DoS).
If specific values for the IPsec parameters local-ip, remote-ip, remote ike-id, and traffic selectors are sent from the peer, a memory leak occurs during every IPsec SA rekey which is carried out with a specific message sequence. This will eventually result in an iked process crash and restart.
The iked process memory consumption can be checked using the below command:
user@host> show system processes extensive | grep iked
PID USERNAME PRI NICE SIZE RES STATE C TIME WCPU COMMAND
56903 root 31 0 4016M 2543M CPU0 0 2:10 10.50% iked
This issue affects Juniper Networks Junos OS:
* All versions earlier than 20.4R3-S9;
* 21.2 versions earlier than 21.2R3-S7;
* 21.3 versions earlier than 21.3R3-S5;
* 21.4 versions earlier than 21.4R3-S4;
* 22.1 versions earlier than 22.1R3-S3;
* 22.2 versions earlier than 22.2R3-S2;
* 22.3 versions earlier than 22.3R3;
* 22.4 versions earlier than 22.4R3;
* 23.2 versions earlier than 23.2R1-S2, 23.2R2.
An Improper Handling of Exceptional Conditions vulnerability in the Class of Service daemon (cosd) of Juniper Networks Junos OS allows an authenticated, network-based attacker with low privileges to cause a limited Denial of Service (DoS).
In a scaled CoS scenario with 1000s of interfaces, when specific low privileged commands, received over NETCONF, SSH or telnet, are handled by cosd on behalf of mgd, the respective child management daemon (mgd) processes will get stuck. In case of (Netconf over) SSH this leads to stuck SSH sessions, so that when the connection-limit for SSH is reached, new sessions can't be established anymore. A similar behavior will be seen for telnet etc.
Stuck mgd processes can be monitored by executing the following command:
user@host> show system processes extensive | match mgd | match sbwait
This issue affects Juniper Networks Junos OS:
* All versions earlier than 20.4R3-S9;
* 21.2 versions earlier than 21.2R3-S7;
* 21.3 versions earlier than 21.3R3-S5;
* 21.4 versions earlier than 21.4R3-S5;
* 22.1 versions earlier than 22.1R3-S4;
* 22.2 versions earlier than 22.2R3-S3;
* 22.3 versions earlier than 22.3R3-S2;
* 22.4 versions earlier than 22.4R3;
* 23.2 versions earlier than 23.2R1-S2, 23.2R2.
An Unsupported Feature in the UI vulnerability in Juniper Networks Junos OS on MX Series and EX9200 Series allows an unauthenticated, network-based attacker to cause partial impact to the integrity of the device.
If the "tcp-reset" option is added to the "reject" action in an IPv6 filter which matches on "payload-protocol", packets are permitted instead of rejected. This happens because the payload-protocol match criteria is not supported in the kernel filter causing it to accept all packets without taking any other action. As a fix the payload-protocol match will be treated the same as a "next-header" match to avoid this filter bypass.
This issue doesn't affect IPv4 firewall filters.
This issue affects Juniper Networks Junos OS on MX Series and EX9200 Series:
* All versions earlier than 20.4R3-S7;
* 21.1 versions earlier than 21.1R3-S5;
* 21.2 versions earlier than 21.2R3-S5;
* 21.3 versions earlier than 21.3R3-S4;
* 21.4 versions earlier than 21.4R3-S4;
* 22.1 versions earlier than 22.1R3-S2;
* 22.2 versions earlier than 22.2R3-S2;
* 22.3 versions earlier than 22.3R2-S2, 22.3R3;
* 22.4 versions earlier than 22.4R1-S2, 22.4R2-S2, 22.4R3.
An Improper Handling of Exceptional Conditions vulnerability in the broadband edge subscriber management daemon (bbe-smgd) of Juniper Networks Junos OS on MX Series allows an attacker directly connected to the vulnerable system who repeatedly flaps DHCP subscriber sessions to cause a slow memory leak, ultimately leading to a Denial of Service (DoS). Memory can only be recovered by manually restarting bbe-smgd.
This issue only occurs if BFD liveness detection for DHCP subscribers is enabled. Systems without BFD liveness detection enabled are not vulnerable to this issue.
Indication of the issue can be observed by periodically executing the 'show system processes extensive' command, which will indicate an increase in memory allocation for bbe-smgd. A small amount of memory is leaked every time a DHCP subscriber logs in, which will become visible over time, ultimately leading to memory starvation.
user@junos> show system processes extensive | match bbe-smgd
13071 root 24 0 415M 201M select 0 0:41 7.28% bbe-smgd{bbe-smgd}
13071 root 20 0 415M 201M select 1 0:04 0.00% bbe-smgd{bbe-smgd}
...
user@junos> show system processes extensive | match bbe-smgd
13071 root 20 0 420M 208M select 0 4:33 0.10% bbe-smgd{bbe-smgd}
13071 root 20 0 420M 208M select 0 0:12 0.00% bbe-smgd{bbe-smgd}
...
This issue affects Juniper Networks Junos OS on MX Series:
* All versions earlier than 20.4R3-S9;
* 21.2 versions earlier than 21.2R3-S7;
* 21.3 versions earlier than 21.3R3-S5;
* 21.4 versions earlier than 21.4R3-S5;
* 22.1 versions earlier than 22.1R3-S4;
* 22.2 versions earlier than 22.2R3-S3;
* 22.3 versions earlier than 22.3R3-S2;
* 22.4 versions earlier than 22.4R2-S2, 22.4R3;
* 23.2 versions earlier than 23.2R1-S1, 23.2R2.