A specially crafted TCP/IP packet may cause a camera recovery image telnet interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware.
A specially crafted TCP/IP packet may cause the camera recovery image web interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware.
An issue was discovered in several Bosch IP cameras for firmware versions 6.32 and higher. A malicious client could potentially succeed in the unauthorized execution of code on the device via the network interface.