In Jenkins Delphix Plugin 3.0.1, a global option for administrators to enable or disable SSL/TLS certificate validation for Data Control Tower (DCT) connections is disabled by default.
In Jenkins Delphix Plugin 3.0.1 through 3.1.0 (both inclusive) a global option for administrators to enable or disable SSL/TLS certificate validation for Data Control Tower (DCT) connections fails to take effect until Jenkins is restarted when switching from disabled validation to enabled validation.
A missing permission check in Jenkins Delphix Plugin 3.0.2 and earlier allows attackers with Overall/Read permission to enumerate credentials IDs of credentials stored in Jenkins.
Jenkins Delphix Plugin 3.0.2 and earlier does not set the appropriate context for credentials lookup, allowing attackers with Overall/Read permission to access and capture credentials they are not entitled to.
Jenkins Delphix Plugin stores credentials unencrypted in its global configuration file on the Jenkins master where they can be viewed by users with access to the master file system.