In ims service, there is a possible unexpected application behavior due to incorrect privilege assignment. This could lead to local denial of service with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06219127; Issue ID: ALPS06219127.
In ims service, there is a possible escalation of privilege due to a missing permission check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06219097; Issue ID: ALPS06219097.
In vpu, there is a possible escalation of privilege due to a missing permission check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS05954679; Issue ID: ALPS05954679.
In connsyslogger, there is a possible symbolic link following due to improper link resolution. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06335038; Issue ID: ALPS06335038.
In Bluetooth, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06198663; Issue ID: ALPS06198663.
In cmdq driver, there is a possible out of bounds read due to an incorrect bounds check. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS05747150; Issue ID: ALPS05747150.
In Bluetooth, there is a possible escalation of privilege due to a missing permission check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06108596; Issue ID: ALPS06108596.
In Bluetooth, there is a possible information disclosure due to incorrect error handling. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06108487; Issue ID: ALPS06108487.
In Bluetooth, there is a possible escalation of privilege due to a missing permission check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06148177; Issue ID: ALPS06148177.
In Bluetooth, there is a possible service crash due to a use after free. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06126814; Issue ID: ALPS06126814.