An Uncontrolled Resource Consumption vulnerability in Fortinet FortiSwitch below 3.6.11, 6.0.6 and 6.2.2, FortiAnalyzer below 6.2.3, FortiManager below 6.2.3 and FortiAP-S/W2 below 6.2.2 may allow an attacker to cause admin webUI denial of service (DoS) via handling special crafted HTTP requests/responses in pieces slowly, as demonstrated by Slow HTTP DoS Attacks.
An external control of system vulnerability in FortiOS may allow an authenticated, regular user to change the routing settings of the device via connecting to the ZebOS component.
In FortiBalancer 400, 1000, 2000 and 3000, a platform-specific remote access vulnerability has been discovered that may allow a remote user to gain privileged access to affected systems using SSH. The vulnerability is caused by a configuration error, and is not the result of an underlying SSH defect.
In FortiBalancer 400, 1000, 2000 and 3000, a platform-specific remote access vulnerability has been discovered that may allow a remote user to gain privileged access to affected systems using SSH. The vulnerability is caused by a configuration error, and is not the result of an underlying SSH defect.
In FortiBalancer 400, 1000, 2000 and 3000, a platform-specific remote access vulnerability has been discovered that may allow a remote user to gain privileged access to affected systems using SSH. The vulnerability is caused by a configuration error, and is not the result of an underlying SSH defect.
An improper neutralization of input vulnerability in FortiWeb allows a remote authenticated attacker to perform a stored cross site scripting attack (XSS) via the Disclaimer Description of a Replacement Message.
A system command injection vulnerability in the FortiAP-S/W2 6.2.1, 6.2.0, 6.0.5 and below, FortiAP 6.0.5 and below and FortiAP-U below 6.0.0 under CLI admin console may allow unauthorized administrators to run arbitrary system level commands via specially crafted ifconfig commands.
An Insufficient Verification of Data Authenticity vulnerability in FortiManager 6.2.1, 6.2.0, 6.0.6 and below may allow an unauthenticated attacker to perform a Cross-Site WebSocket Hijacking (CSWSH) attack.
An improper input validation vulnerability in FortiOS 6.2.1, 6.2.0, 6.0.8 and below until 5.4.0 under admin webUI may allow an attacker to perform an URL redirect attack via a specifically crafted request to the admin initial password change webpage.
An Unsafe Search Path vulnerability in FortiClient EMS online installer 6.2.1 and below may allow a local attacker with control over the directory in which FortiClientEMSOnlineInstaller.exe resides to execute arbitrary code on the system via uploading malicious Filter Library DLL files in that directory.