A vulnerability in the web-based interface allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (CSRF - Cross Site Request Forgery). This requires the victim to be tricked into clicking a malicious link or opening a malicious website while being logged in into the camera.
This vulnerability could allow an attacker to hijack a session while a user is logged in the configuration web page. This vulnerability was discovered by a security researcher in B426 and found during internal product tests in B426-CN/B429-CN, and B426-M and has been fixed already starting from version 3.08 on, which was released on June 2019.
When using http protocol, the user password is transmitted as a clear text parameter for which it is possible to be obtained by an attacker through a MITM attack. This will be fixed starting from Firmware version 3.11.5, which will be released on the 30th of June, 2021.
A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected.
An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can send a crafted link to a user, which will execute javascript code in the context of the user.
An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS).
An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected.
Loading a DLL through an Uncontrolled Search Path Element in Bosch IP Helper up to and including version 1.00.0008 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same application directory as the portable IP Helper application.
Loading a DLL through an Uncontrolled Search Path Element in Bosch BVMS and BVMS Viewer in versions 10.1.0, 10.0.1, 10.0.0 and 9.0.0 and older potentially allows an attacker to execute arbitrary code on a victim's system. This affects both the installer as well as the installed application. This also affects Bosch DIVAR IP 7000 R2, Bosch DIVAR IP all-in-one 5000 and Bosch DIVAR IP all-in-one 7000 with installers and installed BVMS versions prior to BVMS 10.1.1.