A physical attacker with access to the device display via USB-C can send a message to the device which triggers an unsecure copy to a buffer resulting in loss of integrity and a temporary denial-of-service for the stations until they got restarted by the watchdog.
An unauthenticated adjacent attacker can modify configuration by sending specific requests to an API-endpoint resulting in read and write access due to missing authentication.
An unauthenticated remote attacker can use MQTT messages to crash a service on charging stations complying with German Calibration Law, resulting in a temporary denial-of-service for these stations until they got restarted by the watchdog.
An unauthenticated remote attacker can use MQTT messages to trigger out-of-bounds writes in charging stations complying with German Calibration Law, resulting in a loss of integrity for only EichrechtAgents and potential denial-of-service for these stations.
A vulnerability was found in PHPGurukul/Campcodes Cyber Cafe Management System 1.0 and classified as critical. Affected by this issue is some unknown functionality of the file /forgot-password.php. The manipulation of the argument email leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.