Mitsubishielectric:  Security Vulnerabilities
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.
CVSS Score
8.6
EPSS Score
0.003
Published
2022-11-25
Improper Input Validation vulnerability in Mitsubishi Electric GOT2000 Series GT27 model FTP server versions 01.39.000 and prior, Mitsubishi Electric GOT2000 Series GT25 model FTP server versions 01.39.000 and prior and Mitsubishi Electric GOT2000 Series GT23 model FTP server versions 01.39.000 and prior allows a remote authenticated attacker to cause a Denial of Service condition by sending specially crafted command.
CVSS Score
5.3
EPSS Score
0.003
Published
2022-11-24
Cross-site scripting vulnerability in Mitsubishi Electric consumer electronics products (Air Conditioning, Wi-Fi Interface, Refrigerator, HEMS adapter, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator, Smart Switch and Air Purifier) allows a remote unauthenticated attacker to execute an malicious script on a user's browser to disclose information, etc. The wide range of models/versions of Mitsubishi Electric consumer electronics products are affected by this vulnerability. As for the affected product models/versions, see the Mitsubishi Electric's advisory which is listed in [References] section.
CVSS Score
6.1
EPSS Score
0.009
Published
2022-11-08
Cleartext Transmission of Sensitive Information vulnerability due to the use of Basic Authentication for HTTP connections in Mitsubishi Electric consumer electronics products (PHOTOVOLTAIC COLOR MONITOR ECO-GUIDE, HEMS adapter, Wi-Fi Interface, Air Conditioning, Induction hob, Mitsubishi Electric HEMS Energy Measurement Unit, Refrigerator, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator, Smart Switch, Ventilating Fan, Range hood fan, Energy Measurement Unit and Air Purifier) allows a remote unauthenticated attacker to disclose information in the products or cause a denial of service (DoS) condition as a result by sniffing credential information (username and password). The wide range of models/versions of Mitsubishi Electric consumer electronics products are affected by this vulnerability. As for the affected product models/versions, see the Mitsubishi Electric's advisory which is listed in [References] section.
CVSS Score
9.8
EPSS Score
0.007
Published
2022-11-08
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
CVSS Score
7.8
EPSS Score
0.001
Published
2022-07-20
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
CVSS Score
7.8
EPSS Score
0.001
Published
2022-07-20
Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes.
CVSS Score
7.8
EPSS Score
0.002
Published
2022-07-20
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server.
CVSS Score
9.8
EPSS Score
0.073
Published
2022-07-20
Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server.
CVSS Score
9.1
EPSS Score
0.004
Published
2022-07-20
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes.
CVSS Score
7.8
EPSS Score
0.002
Published
2022-07-20