In TIM BPM Suite/ TIM FLOW through 9.1.2 multiple Hibernate Query Language injection vulnerabilities exist which allow a low privileged user to extract passwords of other users and access sensitive data of another user.
In TIM BPM Suite/ TIM FLOW through 9.1.2 multiple SQL injection vulnerabilities exists which allow a low privileged and administrative user to access the database and its content.
In TIM BPM Suite/ TIM FLOW through 9.1.2 multiple Authorization Bypass vulnerabilities exists which allow a low privileged user to download password hashes of other user, access work items of other user, modify restricted content in workflows, modify the applications logo and manipulate the profile of other user.
A vulnerability was found in PHPGurukul Online Course Registration System up to 3.1. This affects an unknown part of the file /enroll.php. The manipulation of the argument studentregno/Pincode/session/department/level/course/sem results in sql injection. The attack may be launched remotely. The exploit has been made public and could be used.
A vulnerability was detected in RainyGao DocSys up to 2.02.36. The affected element is an unknown function of the file src/com/DocSystem/mapping/GroupMemberMapper.xml. Performing a manipulation of the argument searchWord results in sql injection. It is possible to initiate the attack remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
fluidsynth-2.4.6 and earlier versions is vulnerable to Null pointer dereference in fluid_synth_monopoly.c, that can be triggered when loading an invalid midi file.
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,
The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.