Security Vulnerabilities
- CVEs Published In 2020
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which can induce a denial-of-service condition
through a system restart.
In Patient Information Center iX (PICiX) Versions C.02, C.03,
PerformanceBridge Focal Point Version A.01, the product receives input
that is expected to be well-formed (i.e., to comply with a certain
syntax) but it does not validate or incorrectly validates that the input
complies with the syntax, causing the certificate enrollment service to
crash. It does not impact monitoring but prevents new devices from
enrolling.
In Patient Information Center iX (PICiX) Versions C.02, C.03, the
software parses a formatted message or structure but does not handle or
incorrectly handles a length field that is inconsistent with the actual
length of the associated data, causing the application on the
surveillance station to restart.
Huawei smartphones BLA-A09 versions 8.0.0.123(C212),versions earlier than 8.0.0.123(C567),versions earlier than 8.0.0.123(C797);BLA-TL00B versions earlier than 8.1.0.326(C01);Berkeley-L09 versions earlier than 8.0.0.163(C10),versions earlier than 8.0.0.163(C432),Versions earlier than 8.0.0.163(C636),Versions earlier than 8.0.0.172(C10);Duke-L09 versions Duke-L09C10B187, versions Duke-L09C432B189, versions Duke-L09C636B189;HUAWEI P20 versions earlier than 8.0.1.16(C00);HUAWEI P20 Pro versions earlier than 8.1.0.152(C00);Jimmy-AL00A versions earlier than Jimmy-AL00AC00B172;LON-L29D versions LON-L29DC721B192;NEO-AL00D versions earlier than 8.1.0.172(C786);Stanford-AL00 versions Stanford-AL00C00B123;Toronto-AL00 versions earlier than Toronto-AL00AC00B225;Toronto-AL00A versions earlier than Toronto-AL00AC00B225;Toronto-TL10 versions earlier than Toronto-TL10C01B225 have an information vulnerability. A module has a design error that is lack of control of input. Attackers can exploit this vulnerab
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software saves user-provided information into a comma-separated value
(CSV) file, but it does not neutralize or incorrectly neutralizes
special elements that could be interpreted as a command when the file is
opened by spreadsheet software.
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software does not neutralize or incorrectly neutralizes
user-controllable input before it is placed in output that is then used
as a webpage and served to other users. Successful exploitation could
lead to unauthorized access to patient data via a read-only web
application.
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and
PerformanceBridge Focal Point Version A.01, when an actor claims to have
a given identity, the software does not prove or insufficiently proves
the claim is correct.
In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and
prior, the software does not check or incorrectly checks the revocation
status of a certificate, which may cause it to use a compromised
certificate.
A deserialization flaw is present in Taoensso Nippy before 2.14.2. In some circumstances, it is possible for an attacker to create a malicious payload that, when deserialized, will allow arbitrary code to be executed. This occurs because there is automatic use of the Java Serializable interface.
An issue was discovered in InspIRCd 2 before 2.0.28 and 3 before 3.3.0. The mysql module contains a NULL pointer dereference when built against mariadb-connector-c 3.0.5 or newer. When combined with the sqlauth or sqloper modules, this vulnerability can be used for remote crashing of an InspIRCd server by any user able to connect to a server.