Honeywell:  Security Vulnerabilities
Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess Controls (SBC) PCD S-Bus authentication bypass issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication functions on the basis of a MAC/IP whitelist with inactivity timeout to which an authenticated client's MAC/IP is stored. UDP traffic can be spoofed to bypass the whitelist-based access control. Since UDP is stateless, an attacker capable of passively observing traffic can spoof arbitrary messages using the MAC/IP of an authenticated client. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.
CVSS Score
8.1
EPSS Score
0.0
Published
2022-07-28
Saia Burgess Controls (SBC) PCD through 2022-05-06 uses a Broken or Risky Cryptographic Algorithm. According to FSCT-2022-0063, there is a Saia Burgess Controls (SBC) PCD S-Bus weak credential hashing scheme issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication is done by using the S-Bus 'write byte' message to a specific address and supplying a hashed version of the password. The hashing algorithm used is based on CRC-16 and as such not cryptographically secure. An insecure hashing algorithm is used. An attacker capable of passively observing traffic can intercept the hashed credentials and trivially find collisions allowing for authentication without having to bruteforce a keyspace defined by the actual strength of the password. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.
CVSS Score
4.3
EPSS Score
0.0
Published
2022-07-28
Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
CVSS Score
7.5
EPSS Score
0.002
Published
2022-07-28
Honeywell Experion PKS Safety Manager 5.02 uses Hard-coded Credentials. According to FSCT-2022-0052, there is a Honeywell Experion PKS Safety Manager hardcoded credentials issue. The affected components are characterized as: POLO bootloader. The potential impact is: Manipulate firmware. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 serial interface for firmware management purposes. When booting, the Safety Manager exposes the Enea POLO bootloader via this interface. Access to the boot configuration is controlled by means of credentials hardcoded in the Safety Manager firmware. The credentials for the bootloader are hardcoded in the firmware. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize these credentials to control the boot process and manipulate the unauthenticated firmware image (see FSCT-2022-0054).
CVSS Score
4.6
EPSS Score
0.001
Published
2022-07-28
Honeywell Alerton Ascent Control Module (ACM) through 2022-05-04 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller's function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered.
CVSS Score
6.8
EPSS Score
0.001
Published
2022-07-15
Honeywell Alerton Visual Logic through 2022-05-04 allows unauthenticated programming writes from remote users. This enables code to be stored on the controller and then run without verification. A user with malicious intent can send a crafted packet to change and/or stop the program without the knowledge of other users, altering the controller's function. After the programming change, the program needs to be overwritten in order for the controller to restore its original operational function.
CVSS Score
8.8
EPSS Score
0.007
Published
2022-07-15
Honeywell Alerton Ascent Control Module (ACM) through 2022-05-04 allows unauthenticated programming writes from remote users. This enables code to be store on the controller and then run without verification. A user with malicious intent can send a crafted packet to change and/or stop the program without the knowledge of other users, altering the controller's function. After the programming change, the program needs to be overwritten in order for the controller to restore its original operational function.
CVSS Score
8.0
EPSS Score
0.006
Published
2022-07-15
Honeywell Alerton Compass Software 1.6.5 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller's function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered.
CVSS Score
6.5
EPSS Score
0.002
Published
2022-07-15
Matrikon, a subsidary of Honeywell Matrikon OPC Server (all versions) is vulnerable to a condition where a low privileged user allowed to connect to the OPC server to use the functions of the IPersisFile to execute operating system processes with system-level privileges.
CVSS Score
5.8
EPSS Score
0.001
Published
2022-05-26
Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow a video replay attack after ARP cache poisoning has been achieved.
CVSS Score
9.8
EPSS Score
0.014
Published
2022-02-24