Vulnerabilities
Vulnerable Software
Emerson:  Security Vulnerabilities
Improper Input Validation in Emerson GE Automation Proficy Machine Edition v8.0 allows an attacker to cause a denial of service and application crash via crafted traffic from a Man-in-the-Middle (MITM) attack to the component "FrameworX.exe"in the module "fxVPStatcTcp.dll".
CVSS Score
5.3
EPSS Score
0.003
Published
2021-07-30
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access.
CVSS Score
7.5
EPSS Score
0.001
Published
2021-05-20
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The webserver of the affected products allows unvalidated files to be uploaded, which an attacker could utilize to execute arbitrary code.
CVSS Score
9.8
EPSS Score
0.007
Published
2021-05-20
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected webserver applications allow access to stored data that can be obtained by using specially crafted URLs.
CVSS Score
7.5
EPSS Score
0.003
Published
2021-05-20
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications utilize persistent cookies where the session cookie attribute is not properly invalidated, allowing an attacker to intercept the cookies and gain access to sensitive information.
CVSS Score
5.3
EPSS Score
0.002
Published
2021-05-20
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications do not validate webpage input, which could allow an attacker to inject arbitrary HTML code into a webpage. This would allow an attacker to modify the page and display incorrect or undesirable data.
CVSS Score
6.1
EPSS Score
0.002
Published
2021-05-20
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected product’s web interface allows an attacker to route click or keystroke to another page provided by the attacker to gain unauthorized access to sensitive information.
CVSS Score
6.1
EPSS Score
0.002
Published
2021-05-20
Emerson Smart Wireless Gateway 1420 4.6.59 allows non-privileged users (such as the default account 'maint') to perform administrative tasks by sending specially crafted HTTP requests to the application.
CVSS Score
8.8
EPSS Score
0.008
Published
2021-03-10
Incorrect Access Control in Emerson Smart Wireless Gateway 1420 4.6.59 allows remote attackers to obtain sensitive device information from the administrator console without authentication.
CVSS Score
7.5
EPSS Score
0.008
Published
2021-03-10
M&M Software fdtCONTAINER Component in versions below 3.5.20304.x and between 3.6 and 3.6.20304.x is vulnerable to deserialization of untrusted data in its project storage.
CVSS Score
7.3
EPSS Score
0.001
Published
2021-01-22


Contact Us

Shodan ® - All rights reserved