Security Vulnerabilities
- CVEs Published In 2020
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not properly control the allocation and maintenance of a limited
resource, thereby enabling an attacker to influence the amount of
resources consumed, eventually leading to the exhaustion of available
resources.
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
An issue was discovered in MISP before 2.4.132. It can perform an unwanted action because of a POST operation on a form that is not linked to the login page.
InstallBuilder for Qt Windows (versions prior to 20.7.0) installers look for plugins at a predictable location at initialization time, writable by non-admin users. While those plugins are not required, they are loaded if present, which could allow an attacker to plant a malicious library which could result in code execution with the security scope of the installer.
An issue was discovered in Ozeki NG SMS Gateway through 4.17.6. The ASP.net SMS module can be used to read and validate the source code of ASP files. By altering the path, it can be made to read any file on the Operating System, usually with NT AUTHORITY\SYSTEM privileges.
An issue was discovered in Ozeki NG SMS Gateway through 4.17.6. The RSS To SMS module processes XML files in an unsafe manner. This opens the application to an XML External Entity attack that can be used to perform SSRF or read arbitrary local files.
A flaw was found in the Linux kernel in versions before 5.9-rc6. When changing screen size, an out-of-bounds memory write can occur leading to memory corruption or a denial of service. Due to the nature of the flaw, privilege escalation cannot be fully ruled out.
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input
before it is placed in output used as a webpage that is served to other
users.
The Alfresco Reset Password add-on before version 1.2.0 relies on untrusted inputs in a security decision. Intruders can get admin's access to the system using the vulnerability in the project. Impacts all servers where this add-on is installed. The problem is fixed in version 1.2.0