A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request.
An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet.
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler.
An issue was discovered in Tenda AC8 v4.0 AC1200 Dual-band Gigabit Wireless Router AC8v4.0 Firmware 16.03.33.05. The root password of the device is calculated with a static string and the last two octets of the MAC address of the device. This allows an unauthenticated attacker to authenticate with network services on the device.
A vulnerability was detected in Tenda AC1206 15.03.06.23. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.
A flaw has been found in Tenda CH22 1.0.0.1. This vulnerability affects the function formeditUserName of the file /goform/editUserName. Executing manipulation of the argument new_account can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.