Vulnerabilities
Vulnerable Software
Sick:  Security Vulnerabilities
Use of Password Hash Instead of Password for Authentication in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to use a password hash instead of an actual password to login to a valid user account via the REST interface.
CVSS Score
6.2
EPSS Score
0.002
Published
2023-05-15
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote attacker to potentially steal user credentials that are stored in the user’s browsers local storage via cross-site-scripting attacks.
CVSS Score
5.3
EPSS Score
0.0
Published
2023-05-15
Uncontrolled Resource Consumption in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an remote attacker to influence the availability of the webserver by invocing a Slowloris style attack via HTTP requests.
CVSS Score
5.3
EPSS Score
0.002
Published
2023-05-15
Missing Authentication for Critical Function in SICK Flexi Classic and Flexi Soft Gateways with Partnumbers 1042193, 1042964, 1044078, 1044072, 1044073, 1044074, 1099830, 1099832, 1127717, 1069070, 1112296, 1051432, 1102420, 1127487, 1121596, 1121597 allows an unauthenticated remote attacker to influence the availability of the device by changing the IP settings of the device via broadcasted UDP packets.
CVSS Score
7.5
EPSS Score
0.006
Published
2023-05-12
The Flexi Classic and Flexi Soft Gateways SICK UE410-EN3 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN1 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN3S04 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN4 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK FX0-GENT00000 FLEXISOFT EIP GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GMOD00000 FLEXISOFT MOD GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GPNT00000 FLEXISOFT PNET GATEW. with serial number <=2311xxxx with Firmware <=V2.12.0, SICK FX0-GENT00030 FLEXISOFT EIP GATEW.V2 with serial number <=2311xxxx all Firmware versions, SICK FX0-GPNT00030 FLEXISOFT PNET GATEW.V2 with serial number <=2311xxxx all Firmware versions and SICK FX0-GMOD00010 FLEXISOFT MOD GW with serial number <=2311xxxx with Firmware <=V2.11.0 all have Telnet enabled by factory default. No password is set in the default configuration.
CVSS Score
9.8
EPSS Score
0.002
Published
2023-04-19
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
CVSS Score
9.8
EPSS Score
0.024
Published
2023-02-20
Missing Authentication for Critical Function in SICK FX0-GENT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
CVSS Score
9.8
EPSS Score
0.024
Published
2023-02-20
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal).
CVSS Score
9.8
EPSS Score
0.015
Published
2022-12-16
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU62x firmware version < 2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person.
CVSS Score
6.5
EPSS Score
0.001
Published
2022-12-13
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU63x firmware version < v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person.
CVSS Score
6.5
EPSS Score
0.001
Published
2022-12-13


Contact Us