Vulnerabilities
Vulnerable Software
Bosch:  Security Vulnerabilities
An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks.
CVSS Score
5.9
EPSS Score
0.001
Published
2023-12-18
A command injection vulnerability exists in Bosch IP cameras that allows an authenticated user with administrative rights to run arbitrary commands on the OS of the camera.
CVSS Score
7.2
EPSS Score
0.001
Published
2023-12-18
An information disclosure vulnerability was discovered in Bosch IP camera devices allowing an unauthenticated attacker to retrieve information (like capabilities) about the device itself and network settings of the device, disclosing possibly internal network settings if the device is connected to the internet.
CVSS Score
5.3
EPSS Score
0.001
Published
2023-12-18
An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation.
CVSS Score
7.5
EPSS Score
0.001
Published
2023-12-18
A command injection vulnerability exists in RTS VLink Virtual Matrix Software Versions v5 (< 5.7.6) and v6 (< 6.5.0) that allows an attacker to perform arbitrary code execution via the admin web interface.
CVSS Score
8.4
EPSS Score
0.001
Published
2023-09-18
Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network
CVSS Score
8.1
EPSS Score
0.002
Published
2023-06-30
Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request.
CVSS Score
7.1
EPSS Score
0.002
Published
2023-06-15
Due to an error in the software interface to the secure element chip on Bosch IP cameras of family CPP13 and CPP14, the chip can be permanently damaged when enabling the Stream security option (signing of the video stream) with option MD5, SHA-1 or SHA-256.
CVSS Score
4.9
EPSS Score
0.002
Published
2023-06-15
An Improper Access Control vulnerability allows an attacker to access the control panel of the B420 without requiring any sort of authorization or authentication due to the IP based authorization. If an authorized user has accessed a publicly available B420 product using valid credentials, an insider attacker can gain access to the same panel without requiring any sort of authorization. The B420 module was already obsolete at the time this vulnerability was found (The End of Life announcement was made in 2013).
CVSS Score
7.6
EPSS Score
0.002
Published
2023-02-08
An error in the URL handler of the VIDEOJET multi 4000 may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the encoder address can send a crafted link to a user, which will execute JavaScript code in the context of the user.
CVSS Score
5.8
EPSS Score
0.005
Published
2022-10-27


Contact Us