Vulnerabilities
Vulnerable Software
Security Vulnerabilities
D-Link Nuclias Connect firmware versions <= 1.3.1.4 contain a stored cross-site scripting (XSS) vulnerability due to improper sanitization of the 'Network' field when editing the configuration, creating a profile, and adding a network. An authenticated attacker can inject arbitrary JavaScript to be executed in the context of other users viewing the profile entry. NOTE: D-Link states that a fix is under development.
CVSS Score
5.4
EPSS Score
0.0
Published
2025-10-16
D-Link Nuclias Connect firmware versions <= 1.3.1.4 contain an observable response discrepancy vulnerability. The application's 'Login' endpoint returns distinct JSON responses depending on whether the supplied username is associated with an existing account. Because the responses differ in the `error.message`string value, an unauthenticated remote attacker can enumerate valid usernames/accounts on the server. NOTE: D-Link states that a fix is under development.
CVSS Score
5.3
EPSS Score
0.0
Published
2025-10-16
D-Link Nuclias Connect firmware versions <= 1.3.1.4 contain an observable response discrepancy vulnerability. The application's 'Forgot Password' endpoint returns distinct JSON responses depending on whether the supplied email address is associated with an existing account. Because the responses differ in the `data.exist` boolean value, an unauthenticated remote attacker can enumerate valid email addresses/accounts on the server. NOTE: D-Link states that a fix is under development.
CVSS Score
5.3
EPSS Score
0.0
Published
2025-10-16
In the ConnectWise Automate Agent, communications could be configured to use HTTP instead of HTTPS. In such cases, an on-path threat actor with a man-in-the-middle network position could intercept, modify, or replay agent-server traffic. Additionally, the encryption method used to obfuscate some communications over the HTTP channel is updated in the Automate 2025.9 patch to enforce HTTPS for all agent communications.
CVSS Score
9.6
EPSS Score
0.0
Published
2025-10-16
OPEXUS FOIAXpress allows a remote, unauthenticated attacker to reset the administrator password. Fixed in FOIAXpress version 11.13.2.0.
CVSS Score
9.8
EPSS Score
0.001
Published
2025-10-16
Frappe is a full-stack web application framework. Prior to 14.98.0 and 15.83.0, an open redirect was possible through the redirect argument on the login page, if a specific type of URL was passed in. This vulnerability is fixed in 14.98.0 and 15.83.0.
CVSS Score
6.1
EPSS Score
0.0
Published
2025-10-16
Envoy is a cloud-native, open source edge and service proxy. Prior to 1.36.1, 1.35.5, 1.34.9, and 1.33.10, large requests and responses can potentially trigger TCP connection pool crashes due to flow control management in Envoy. It will happen when the connection is closing but upstream data is still coming, resulting in a buffer watermark callback nullptr reference. The vulnerability impacts TCP proxy and HTTP 1 & 2 mixed use cases based on ALPN. This vulnerability is fixed in 1.36.1, 1.35.5, 1.34.9, and 1.33.10.
CVSS Score
7.5
EPSS Score
0.0
Published
2025-10-16
LibreNMS is a community-based GPL-licensed network monitoring system. LibreNMS <= 25.8.0 contains a Stored Cross-Site Scripting (XSS) vulnerability in the Alert Transports management functionality. When an administrator creates a new Alert Transport, the value of the Transport name field is stored and later rendered in the Transports column of the Alert Rules page without proper input validation or output encoding. This leads to arbitrary JavaScript execution in the admin’s browser. This vulnerability is fixed in 25.10.0.
CVSS Score
5.5
EPSS Score
0.0
Published
2025-10-16
LibreNMS is a community-based GPL-licensed network monitoring system. The alert rule name in the Alerts > Alert Rules page is not properly sanitized, and can be used to inject HTML code. This vulnerability is fixed in 25.10.0.
CVSS Score
3.8
EPSS Score
0.0
Published
2025-10-16
Icinga 2 is an open source monitoring system. From 2.10.0 to before 2.15.1, 2.14.7, and 2.13.13, the safe-reload script (also used during systemctl reload icinga2) and logrotate configuration shipped with Icinga 2 read the PID of the main Icinga 2 process from a PID file writable by the daemon user, but send the signal as the root user. This can allow the Icinga user to send signals to processes it would otherwise not permitted to. A fix is included in the following Icinga 2 versions: 2.15.1, 2.14.7, and 2.13.13.
CVSS Score
4.4
EPSS Score
0.0
Published
2025-10-16


Contact Us

Shodan ® - All rights reserved