Vulnerabilities
Vulnerable Software
Schneider-Electric:  Security Vulnerabilities
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22747.
CVSS Score
3.9
EPSS Score
0.001
Published
2021-05-26
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746.
CVSS Score
3.9
EPSS Score
0.001
Published
2021-05-26
Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP.
CVSS Score
7.5
EPSS Score
0.006
Published
2021-05-26
Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert
CVSS Score
7.8
EPSS Score
0.001
Published
2021-05-26
Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker.
CVSS Score
9.8
EPSS Score
0.02
Published
2021-05-26
Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a code execution issue when an attacker loads unauthorized code on the web server.
CVSS Score
7.8
EPSS Score
0.0
Published
2021-05-26
Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause shell access when unauthorized code is loaded into the system folder.
CVSS Score
7.8
EPSS Score
0.0
Published
2021-05-26
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
CVSS Score
7.8
EPSS Score
0.002
Published
2021-04-13
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.
CVSS Score
8.8
EPSS Score
0.177
Published
2021-04-13
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files.
CVSS Score
7.8
EPSS Score
0.038
Published
2021-04-13


Contact Us

Shodan ® - All rights reserved