In K7 Antivirus Premium before 15.1.0.53, user-controlled input to the K7Sentry device is not sufficiently authenticated: a local user with a LOW integrity process can access a raw hard disk by sending a specific IOCTL.
In K7 Total Security before 15.1.0.305, user-controlled input to the K7Sentry device is not sufficiently sanitized: the user-controlled input can be used to compare an arbitrary memory address with a fixed value, which in turn can be used to read the contents of arbitrary memory. Similarly, the product crashes upon a \\.\K7Sentry DeviceIoControl call with an invalid kernel pointer.
K7Sentry.sys in K7 Computing Ultimate Security, Anti-Virus Plus, and Total Security before 14.2.0.253 allows local users to write to arbitrary memory locations, and consequently gain privileges, via a crafted 0x95002570, 0x95002574, 0x95002580, 0x950025a8, 0x950025ac, or 0x950025c8 IOCTL call.