Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting.
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally.
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed.
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.