Vulnerabilities
Vulnerable Software
Tenda:  >> Ac10  Security Vulnerabilities
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via cloneType2.
CVSS Score
7.5
EPSS Score
0.006
Published
2025-04-17
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serviceName2.
CVSS Score
4.6
EPSS Score
0.002
Published
2025-04-15
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serverName2.
CVSS Score
4.6
EPSS Score
0.002
Published
2025-04-15
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2.
CVSS Score
9.8
EPSS Score
0.005
Published
2025-04-15
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function ShutdownSetAdd of the file /goform/ShutdownSetAdd. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVSS Score
8.7
EPSS Score
0.007
Published
2025-04-03
Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the parameter ssid.
CVSS Score
9.8
EPSS Score
0.004
Published
2025-02-20
Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variable, which is directly used in the doSystemCmd function, causing an arbitrary command execution.
CVSS Score
9.8
EPSS Score
0.012
Published
2025-02-20
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVSS Score
8.6
EPSS Score
0.058
Published
2025-01-17
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVSS Score
8.7
EPSS Score
0.012
Published
2024-11-15
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVSS Score
8.7
EPSS Score
0.012
Published
2024-11-11


Contact Us

Shodan ® - All rights reserved