This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R6020, R6080, R6120, R6220, R6260, R6700v2, R6800, R6900v2, R7450, JNR3210, WNR2020, Nighthawk AC2100, and Nighthawk AC2400 routers. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the mini_httpd service, which listens on TCP port 80 by default. When parsing the funjsq_access_token parameter, the process does not properly validate a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-11653.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R7450 1.2.0.62_1.0.1 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the mini_httpd service, which listens on TCP port 80 by default. The issue results from improper state tracking in the password recovery process. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-11365.
This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of NETGEAR R7450 1.2.0.62_1.0.1 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the SOAP API endpoint, which listens on TCP port 80 by default. The issue results from the lack of proper access control. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-11559.
Certain NETGEAR devices are affected by authentication bypass. This affects D6200 before 1.1.00.40, D7000 before 1.0.1.78, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.26, JR6150 before 1.0.1.26, R6120 before 1.0.0.66, R6220 before 1.1.0.100, R6260 before 1.1.0.66, R6700v2 before 1.2.0.62, R6800 before 1.2.0.62, R6900v2 before 1.2.0.62, AC2100 before 1.2.0.62, AC2400 before 1.2.0.62, AC2600 before 1.2.0.62, R7450 before 1.2.0.62, and WNR2020 before 1.1.0.62.
Certain NETGEAR devices are affected by authentication bypass. This affects D6200 before 1.1.00.36, D7000 before 1.0.1.74, PR2000 before 1.0.0.30, R6020 before 1.0.0.42, R6050 before 1.0.1.22, JR6150 before 1.0.1.22, R6080 before 1.0.0.42, R6120 before 1.0.0.66, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.64, R6700v2 before 1.2.0.62, R6800 before 1.2.0.62, R69002 before 1.2.0.62, and WNR2020 before 1.1.0.62.
Certain NETGEAR devices are affected by a hardcoded password. This affects D6200 before 1.1.00.36, D7000 before 1.0.1.74, PR2000 before 1.0.0.30, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.24, JR6150 before 1.0.1.24, R6120 before 1.0.0.48, R6220 before 1.1.0.86, R6230 before 1.1.0.86, R6260 before 1.1.0.64, R6700v2 before 1.2.0.62, R6800 before 1.2.0.62, R6900v2 before 1.2.0.62, and WNR2020 before 1.1.0.62.
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6200 before 1.1.00.36, D7000 before 1.0.1.74, PR2000 before 1.0.0.28, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.24, JR6150 before 1.0.1.24, R6120 before 1.0.0.48, R6220 before 1.1.0.86, R6230 before 1.1.0.86, R6260 before 1.1.0.64, R6700v2 before 1.2.0.62, R6800 before 1.2.0.62, R6900v2 before 1.2.0.62, and WNR2020 before 1.1.0.62.