A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions.
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access Project resources. These missing checks may result in remote code execution. This affects NI VeriStand 2024 Q2 and prior versions.
A directory path traversal vulnerability exists when loading a vsmodel file in NI VeriStand that may result in remote code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .vsmodel file. This vulnerability affects VeriStand 2024 Q2 and prior versions.
A deserialization of untrusted data vulnerability exists in NI VeriStand DataLogging Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions.
A deserialization of untrusted data vulnerability exists in NI VeriStand Waveform Streaming Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions.
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access File Transfer resources. These missing checks may result in information disclosure or remote code execution. This affects NI VeriStand 2024 Q2 and prior versions.
An out-of-date version of Redis shipped with NI SystemLink Server is susceptible to multiple vulnerabilities, including CVE-2022-24834. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service.
An incorrect permission in the installation directory for the shared NI SystemLink Server KeyValueDatabase service may result in information disclosure via local access. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service.
An integer overflow vulnerability due to improper input validation when reading TDMS files in LabVIEW may result in an infinite loop. Successful exploitation requires an attacker to provide a user with a specially crafted TDMS file. This vulnerability affects LabVIEW 2024 Q1 and prior versions.