The affected application lacks proper validation of user-supplied data when parsing project files (e.g., CSP). This could lead to an out-of-bounds read in Cscape!CANPortMigration. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.
Cscape Envision RV version 4.60 is vulnerable to an out-of-bounds read vulnerability when parsing project (i.e. HMI) files. The product lacks proper validation of user-supplied data, which could result in reads past the end of allocated data structures. An attacker could leverage these vulnerabilities to execute arbitrary code in the context of the current process.
Cscape Envision RV version 4.60 is vulnerable to an out-of-bounds write vulnerability when parsing project (i.e. HMI) files. The product lacks proper validation of user-supplied data, which could result in writes past the end of allocated data structures. An attacker could leverage these vulnerabilities to execute arbitrary code in the context of the current process.
Cscape Envision RV version 4.60 is vulnerable to an out-of-bounds write vulnerability when parsing project (i.e. HMI) files. The product lacks proper validation of user-supplied data, which could result in writes past the end of allocated data structures. An attacker could leverage these vulnerabilities to execute arbitrary code in the context of the current process.
Horner Automation’s RCC 972 with firmware version 15.40 has a static encryption key on the device. This could allow an attacker to perform unauthorized changes to the device, remotely execute arbitrary code, or cause a denial-of-service condition.
Horner Automation’s RCC 972 firmware version 15.40 contains global variables. This could allow an attacker to read out sensitive values and variable keys from the device.
The Config-files of Horner Automation’s RCC 972 with firmware version 15.40 are encrypted with weak XOR encryption vulnerable to reverse engineering. This could allow an attacker to obtain credentials to run services such as File Transfer Protocol (FTP) and Hypertext Transfer Protocol (HTTP).
Horner Automation's Cscape version 9.90 SP 6 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory read.
Horner Automation's Cscape version 9.90 SP7 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by writing outside the memory buffer.
Horner Automation's Cscape version 9.90 SP 7 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory write.