Vulnerabilities
Vulnerable Software
Schneider-Electric:  Security Vulnerabilities
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVSS Score
8.2
EPSS Score
0.003
Published
2022-06-02
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVSS Score
8.3
EPSS Score
0.01
Published
2022-06-02
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
CVSS Score
9.8
EPSS Score
0.024
Published
2022-04-14
A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneider Electric Software Update (SESU) SUT Service component (V2.1.1 to V2.3.0)
CVSS Score
7.3
EPSS Score
0.01
Published
2022-04-13
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
CVSS Score
9.1
EPSS Score
0.022
Published
2022-04-13
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
CVSS Score
9.1
EPSS Score
0.031
Published
2022-04-13
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
CVSS Score
7.8
EPSS Score
0.261
Published
2022-04-13
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a remote system controlled by an attacker. Affected Product: SCADAPack Workbench (6.6.8a and prior)
CVSS Score
5.5
EPSS Score
0.01
Published
2022-04-13
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.
CVSS Score
6.8
EPSS Score
0.002
Published
2022-04-03
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.
CVSS Score
6.8
EPSS Score
0.004
Published
2022-04-03