Security Vulnerabilities
- CVEs Published In 2022
Delta Electronics DX-2100-L1-CN 2.42 is vulnerable to Cross Site Scripting (XSS) via lform/urlfilter.
RCE in SPIP 3.1.13 through 4.1.2 allows remote authenticated users to execute arbitrary code via the _oups parameter.
wasm3 commit 7890a2097569fde845881e0b352d813573e371f9 was discovered to contain a segmentation fault via the component op_CallIndirect at /m3_exec.h.
Due to the lack of adequately implemented access-control rules, all versions Kingspan TMS300 CS are vulnerable to an attacker viewing and modifying the application settings without authenticating by accessing a specific uniform resource locator (URL) on the webserver.
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to
attackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system.
The csaf_provider package before 0.8.2 allows XSS via a crafted CSAF document uploaded as text/html. The endpoint upload allows valid CSAF advisories (JSON format) to be uploaded with Content-Type text/html and filenames ending in .html. When subsequently accessed via web browser, these advisories are served and interpreted as HTML pages. Such uploaded advisories can contain JavaScript code that will execute within the browser context of users inspecting the advisory.
Certain Linear eMerge E3-Series devices are vulnerable to XSS via the type parameter (e.g., to the badging/badge_template_v0.php component). This affects 0.32-08f, 0.32-07p, 0.32-07e, 0.32-09c, 0.32-09b, 0.32-09a, and 0.32-08e.
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
The Image Hover Effects Ultimate plugin for WordPress is vulnerable to Stored Cross-Site Scripting via several values that can be added to an Image Hover in versions 9.8.1 to 9.8.4 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. By default, the plugin only allows administrators access to edit Image Hovers, however, if a site admin makes the plugin's features available to lower privileged users through the 'Who Can Edit?' setting then this can be exploited by those users.