Vulnerabilities
Vulnerable Software
Mitsubishielectric:  Security Vulnerabilities
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
CVSS Score
7.5
EPSS Score
0.006
Published
2020-11-02
Uncontrolled resource consumption vulnerability in Ethernet Port on MELSEC iQ-R, Q and L series CPU modules (R 00/01/02 CPU firmware versions '20' and earlier, R 04/08/16/32/120 (EN) CPU firmware versions '52' and earlier, R 08/16/32/120 SFCPU firmware versions '22' and earlier, R 08/16/32/120 PCPU all versions, R 08/16/32/120 PSFCPU all versions, R 16/32/64 MTCPU all versions, Q03 UDECPU, Q 04/06/10/13/20/26/50/100 UDEHCPU serial number '22081' and earlier , Q 03/04/06/13/26 UDVCPU serial number '22031' and earlier, Q 04/06/13/26 UDPVCPU serial number '22031' and earlier, Q 172/173 DCPU all versions, Q 172/173 DSCPU all versions, Q 170 MCPU all versions, Q 170 MSCPU all versions, L 02/06/26 CPU (-P) and L 26 CPU - (P) BT all versions) allows a remote unauthenticated attacker to stop the Ethernet communication functions of the products via a specially crafted packet, which may lead to a denial of service (DoS) condition .
CVSS Score
7.5
EPSS Score
0.03
Published
2020-11-02
Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
CVSS Score
9.8
EPSS Score
0.009
Published
2020-11-02
Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
CVSS Score
7.5
EPSS Score
0.006
Published
2020-11-02
NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
CVSS Score
7.5
EPSS Score
0.006
Published
2020-11-02
Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
CVSS Score
9.8
EPSS Score
0.007
Published
2020-11-02
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
CVSS Score
9.8
EPSS Score
0.005
Published
2020-10-05
A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
CVSS Score
9.8
EPSS Score
0.022
Published
2020-07-16
A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.
CVSS Score
9.1
EPSS Score
0.009
Published
2020-07-16
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
CVSS Score
7.5
EPSS Score
0.002
Published
2020-07-16


Contact Us

Shodan ® - All rights reserved