A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)
A vulnerability has been identified in SENTRON powermanager V3 (All versions). The affected application assigns improper access rights to a specific folder containing configuration files. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application writes sensitive data, such as usernames and passwords in log files. A local attacker with access to the log files could use this information to launch further attacks.
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application does not properly handle the import of large configuration files. A local attacker could import a specially crafted file which could lead to a denial-of-service condition of the application service.
In BIND 9.3.0 -> 9.11.35, 9.12.0 -> 9.16.21, and versions 9.9.3-S1 -> 9.11.35-S1 and 9.16.8-S1 -> 9.16.21-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.18 of the BIND 9.17 development branch, exploitation of broken authoritative servers using a flaw in response processing can cause degradation in BIND resolver performance. The way the lame cache is currently designed makes it possible for its internal data structures to grow almost infinitely, which may cause significant delays in client query processing.
The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal
The gmp plugin in strongSwan before 5.9.4 has a remote integer overflow via a crafted certificate with an RSASSA-PSS signature. For example, this can be triggered by an unrelated self-signed CA certificate sent by an initiator. Remote code execution cannot occur.