Security Vulnerabilities
- CVEs Published In 2020
Contentful through 2020-05-21 for Python allows reflected XSS, as demonstrated by the api parameter to the-example-app.py.
A flaw was found in Moodle versions 3.8 before 3.8.3, 3.7 before 3.7.6, 3.6 before 3.6.10, 3.5 before 3.5.12 and earlier unsupported versions. It was possible to create a SCORM package in such a way that when added to a course, it could be interacted with via web services in order to achieve remote code execution.
An issue was discovered in libexif before 0.6.22. Several buffer over-reads in EXIF MakerNote handling could lead to information disclosure and crashes. This is different from CVE-2020-0093.
An issue was discovered in libexif before 0.6.22. An unrestricted size in handling Canon EXIF MakerNote data could lead to consumption of large amounts of compute time for decoding EXIF data.
During installation or upgrade to Software House C•CURE 9000 v2.70 and American Dynamics victor Video Management System v5.2, the credentials of the user used to perform the installation or upgrade are logged in a file. The install log file persists after the installation.
There is an information leakage vulnerability in some Huawei products. An unauthenticated, adjacent attacker could exploit this vulnerability to decrypt data. Successful exploitation may leak information randomly. Affected product versions include: Anne-AL00 Versions earlier than 9.1.0.331(C675E9R1P3T8); Berkeley-L09 Versions earlier than 10.0.1.1(C675R1); CD16-10 Versions earlier than 10.0.2.8; CD17-10 Versions earlier than 10.0.2.8; CD17-16 Versions earlier than 10.0.2.8; CD18-10 Versions earlier than 10.0.2.8; CD18-16 Versions earlier than 10.0.2.8; Columbia-TL00B Versions earlier than 9.0.0.187(C01E181R1P20T8); E6878-370 Versions earlier than 10.0.5.1(H610SP10C00); HUAWEI P30 lite Versions earlier than 10.0.0.185(C605E3R1P3), Versions earlier than 10.0.0.197(C432E8R2P7); HUAWEI nova 4e Versions earlier than 10.0.0.158(C00E64R1P9); Honor 10 Lite 9.0.1.113(C675E11R1P12); LelandP-L22A Versions earlier than 9.1.0.166(C675E5R1P4T8); Marie-AL00AX Versions earlier than 10.0.0.158(C00E64R1P9); Marie-AL00AY Versions earlier than 10.0.0.158(C00E64R1P9); Marie-AL00BX Versions earlier than 10.0.0.158(C00E64R1P9); Marie-L03BX Versions earlier than 10.0.0.188(C605E5R1P1); Marie-L21BX Versions earlier than 10.0.0.188(C432E4R4P1), Versions earlier than 10.0.0.188(C461E5R3P1); Marie-L22BX Versions earlier than 10.0.0.188(C636E3R3P1); Marie-L23BX Versions earlier than 10.0.0.188(C605E5R1P1); TC5200-16 Versions earlier than 10.0.2.8; WS5200-11 Versions earlier than 10.0.2.8; WS5200-12 Versions earlier than 10.0.2.23; WS5200-16 Versions earlier than 10.0.2.8; WS5200-17 Versions earlier than 10.0.2.23; WS5800-10 Versions earlier than 10.0.3.27; WS6500-10 Versions earlier than 10.0.2.8; WS6500-16 Versions earlier than 10.0.2.8
E6878-370 with versions of 10.0.3.1(H557SP27C233), 10.0.3.1(H563SP1C00), 10.0.3.1(H563SP1C233) has a use after free vulnerability. The software references memory after it has been freed in certain scenario, the attacker does a series of crafted operations through web portal, successful exploit could cause a use after free condition which may lead to malicious code execution.
Relative path traversal in Druva inSync Windows Client 6.6.3 allows a local, unauthenticated attacker to execute arbitrary operating system commands with SYSTEM privileges.
netius prior to 1.17.58 is vulnerable to HTTP Request Smuggling. HTTP pipelining issues and request smuggling attacks might be possible due to incorrect Transfer encoding header parsing which could allow for CL:TE or TE:TE attacks.
Element OS prior to version 12.0 and Element HealthTools prior to version 2020.04.01.04 are susceptible to a vulnerability which when successfully exploited could lead to disclosure of sensitive information.