A flaw has been found in Comfast CF-N1 2.6.0. Affected is the function ntp_timezone of the file /usr/bin/webmgnt. Executing manipulation of the argument timestr can lead to command injection. The attack may be launched remotely. The exploit has been published and may be used.
A weakness has been identified in LB-LINK BL-X26 1.2.8. The impacted element is an unknown function of the file /goform/set_hidessid_cfg of the component HTTP Handler. This manipulation of the argument enable causes os command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
A security vulnerability has been detected in LB-LINK BL-X26 1.2.8. This affects an unknown function of the file /goform/set_blacklist of the component HTTP Handler. Such manipulation of the argument mac leads to os command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was detected in Comfast CF-N1 2.6.0. This impacts the function multi_pppoe of the file /usr/bin/webmgnt. Performing manipulation of the argument phy_interface results in command injection. The attack may be initiated remotely. The exploit is now public and may be used.
A security flaw has been discovered in TOTOLINK X2000R up to 2.0.0. The affected element is an unknown function of the file /etc/shadow.sample of the component Administrative Interface. The manipulation results in use of default credentials. Attacking locally is a requirement. Attacks of this nature are highly complex. The exploitability is described as difficult. The exploit has been released to the public and may be exploited.
Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request.
An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet.
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function cgiMain of the file /cgi-bin/upload.cgi. Executing manipulation of the argument filename can lead to os command injection. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was identified in seeedstudio ReSpeaker LinkIt7688. Impacted is an unknown function of the file /etc/shadow of the component Administrative Interface. The manipulation leads to use of default credentials. An attack has to be approached locally. A high degree of complexity is needed for the attack. The exploitability is considered difficult. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.