Vulnerabilities
Vulnerable Software
Security Vulnerabilities - CVEs Published In November 2018
An issue was discovered on Samsung 840 EVO and 850 EVO devices (only in "ATA high" mode, not vulnerable in "TCG" or "ATA max" mode), Samsung T3 and T5 portable drives, and Crucial MX100, MX200 and MX300 devices. Absence of a cryptographic link between the password and the Disk Encryption Key allows attackers with privileged access to SSD firmware full access to encrypted data.
CVSS Score
4.0
EPSS Score
0.002
Published
2018-11-20
An issue was discovered on Samsung 840 EVO devices. Vendor-specific commands may allow access to the disk-encryption key.
CVSS Score
4.2
EPSS Score
0.071
Published
2018-11-20
Cleartext Storage of credentials in the iSmartAlarmData.xml configuration file in the iSmartAlarm application through 2.0.8 for Android allows an attacker to retrieve the username and password.
CVSS Score
6.8
EPSS Score
0.001
Published
2018-11-20
Insecure Cryptographic Storage of credentials in com.vestiacom.qbeecamera_preferences.xml in the QBee Cam application through 1.0.5 for Android allows an attacker to retrieve the username and password.
CVSS Score
9.8
EPSS Score
0.008
Published
2018-11-20
Incorrect access control for the diagnostic files of the iSmartAlarm Cube One through 2.2.4.10 allows an attacker to retrieve them via a specifically crafted TCP request to port 12345 and 22306, and access sensitive information from the device.
CVSS Score
5.3
EPSS Score
0.018
Published
2018-11-20
DENX U-Boot through 2018.09-rc1 has a remotely exploitable buffer overflow via a malicious TFTP server because TFTP traffic is mishandled. Also, local exploitation can occur via a crafted kernel image.
CVSS Score
9.8
EPSS Score
0.005
Published
2018-11-20
DENX U-Boot through 2018.09-rc1 has a locally exploitable buffer overflow via a crafted kernel image because filesystem loading is mishandled.
CVSS Score
7.8
EPSS Score
0.001
Published
2018-11-20
An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Insecure permissions in a service interface may allow authenticated attackers in the adjacent network to execute arbitrary commands on the operating system.
CVSS Score
8.0
EPSS Score
0.003
Published
2018-11-20
An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Weak access credentials may enable attackers in the adjacent network to gain unauthorized service access via a service interface.
CVSS Score
8.8
EPSS Score
0.003
Published
2018-11-20
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 (Serial Number below KQ0400000 or KS0400000) and cobas h 232 before 04.00.04 (Serial Number above KQ0400000 or KS0400000). Improper access control to a service command allows attackers in the adjacent network to execute arbitrary code on the system through a crafted Poct1-A message.