The application was vulnerable to Cross-Site Request Forgery (CSRF) attacks, allowing an attacker to coerce users into sending malicious requests to the site to delete their account, or in rare circumstances, hijack their account and create other admin accounts.
Javascript injection in PDFtron in M-Files Hubshare before 3.3.10.9 allows authenticated attackers to perform an account takeover via a crafted PDF upload.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
Forma LMS version 3.1.0 and earlier are affected by an Cross-Site scripting vulnerability, that could allow a remote attacker to inject javascript code on the “back_url” parameter in appLms/index.php?modname=faq&op=play function. The exploitation of this vulnerability could allow an attacker to steal the user´s cookies in order to log in to the application.
Forma LMS on its 3.1.0 version and earlier is vulnerable to a SQL injection vulnerability. The exploitation of this vulnerability could allow an authenticated attacker (with the role of student) to perform a SQL injection on the 'search[value] parameter in the appLms/ajax.server.php?r=mycertificate/getMyCertificates' function in order to dump the entire database.
There is a vulnerability on Forma LMS version 3.1.0 and earlier that could allow an authenticated attacker (with the role of student) to privilege escalate in order to upload a Zip file through the SCORM importer feature. The exploitation of this vulnerability could lead to a remote code injection.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.