Security Vulnerabilities
- CVEs Published In September 2021
A stored cross-site scripting issue impacts certain areas of the Web UI for Code Insight v7.x releases up to and including 2020 R1 (7.11.0-64).
An elevated privileges issue related to Spring MVC calls impacts Code Insight v7.x releases up to and including 2020 R1 (7.11.0-64).
nLight ECLYPSE (nECY) system Controllers running software prior to 1.17.21245.754 contain a default key vulnerability. The nECY does not force a change to the key upon the initial configuration of an affected device. nECY system controllers utilize an encrypted channel to secure SensorViewTM configuration and monitoring software and nECY to nECY communications. Impacted devices are at risk of exploitation. A remote attacker with IP access to an impacted device could submit lighting control commands to the nECY by leveraging the default key. A successful attack may result in the attacker gaining the ability to modify lighting conditions or gain the ability to update the software on lighting devices. The impacted key is referred to as the SensorView Password in the nECY nLight Explorer Interface and the Gateway Password in the SensorView application. An attacker cannot authenticate to or modify the configuration or software of the nECY system controller.
An issue was discovered in CMS Made Simple 2.2.8. It is possible to achieve unauthenticated path traversal in the CGExtensions module (in the file action.setdefaulttemplate.php) with the m1_filename parameter; and through the action.showmessage.php file, it is possible to read arbitrary file content (by using that path traversal with m1_prefname set to cg_errormsg and m1_resettodefault=1).
Improper input validation in the National Instruments NI-PAL driver in versions 20.0.0 and prior may allow a privileged user to potentially enable escalation of privilege via local access.
XSS Hunter Express before 2021-09-17 does not properly enforce authentication requirements for paths.
The Device42 Remote Collector before 17.05.01 does not sanitize user input in its SNMP Connectivity utility. This allows an authenticated attacker (with access to the console application) to execute arbitrary OS commands and escalate privileges.
The Device42 Main Appliance before 17.05.01 does not sanitize user input in its Nmap Discovery utility. An attacker (with permissions to add or edit jobs run by this utility) can inject an extra argument to overwrite arbitrary files as the root user on the Remote Collector.
XML Entity Expansion injection vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 September 2021 Update allows a local user to initiate high CPU and memory consumption resulting in a Denial of Service attack through carefully editing the EPDeploy.xml file and then executing the setup process.
Improper privileges management vulnerability in McAfee Endpoint Security (ENS) Windows prior to 10.7.0 September 2021 Update allows local users to access files which they would otherwise not have access to via manipulating junction links to redirect McAfee folder operations to an unintended location.