Security Vulnerabilities
- CVEs Published In August 2020
A vulnerability exists in The EdgeMax EdgeSwitch firmware <v1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection.
In BIND 9.15.6 -> 9.16.5, 9.17.0 -> 9.17.3, An attacker who can establish a TCP connection with the server and send data on that connection can exploit this to trigger the assertion failure, causing the server to exit.
In BIND 9.14.0 -> 9.16.5, 9.17.0 -> 9.17.3, If a server is configured with both QNAME minimization and 'forward first' then an attacker who can send queries to it may be able to trigger the condition that will cause the server to crash. Servers that 'forward only' are not affected.
In BIND 9.0.0 -> 9.11.21, 9.12.0 -> 9.16.5, 9.17.0 -> 9.17.3, also affects 9.9.3-S1 -> 9.11.21-S1 of the BIND 9 Supported Preview Edition, An attacker on the network path for a TSIG-signed request, or operating the server receiving the TSIG-signed request, could send a truncated response to that request, triggering an assertion failure, causing the server to exit. Alternately, an off-path attacker would have to correctly guess when a TSIG-signed request was sent, along with other characteristics of the packet and message, and spoof a truncated response to trigger an assertion failure, causing the server to exit.
In BIND 9.10.0 -> 9.11.21, 9.12.0 -> 9.16.5, 9.17.0 -> 9.17.3, also affects 9.10.5-S1 -> 9.11.21-S1 of the BIND 9 Supported Preview Edition, An attacker that can reach a vulnerable system with a specially crafted query packet can trigger a crash. To be vulnerable, the system must: * be running BIND that was built with "--enable-native-pkcs11" * be signing one or more zones with an RSA key * be able to receive queries from a possible attacker
In BIND 9.9.12 -> 9.9.13, 9.10.7 -> 9.10.8, 9.11.3 -> 9.11.21, 9.12.1 -> 9.16.5, 9.17.0 -> 9.17.3, also affects 9.9.12-S1 -> 9.9.13-S1, 9.11.3-S1 -> 9.11.21-S1 of the BIND 9 Supported Preview Edition, An attacker who has been granted privileges to change a specific subset of the zone's content could abuse these unintended additional privileges to update other contents of the zone.
Diebold Nixdorf ProCash 2100xe USB ATMs running Wincor Probase version 1.1.30 do not encrypt, authenticate, or verify the integrity of messages between the CCDM and the host computer, allowing an attacker with physical access to internal ATM components to commit deposit forgery by intercepting and modifying messages to the host computer, such as the amount and value of currency being deposited.
NCR SelfServ ATMs running APTRA XFS 05.01.00 or earlier do not authenticate or protect the integrity of USB HID communications between the currency dispenser and the host computer, permitting an attacker with physical access to internal ATM components the ability to inject a malicious payload and execute arbitrary code with SYSTEM privileges on the host computer by causing a buffer overflow on the host.
The currency dispenser of NCR SelfSev ATMs running APTRA XFS 05.01.00 or earlier does not adequately authenticate session key generation requests from the host computer, allowing an attacker with physical access to internal ATM components to issue valid commands to dispense currency by generating a new session key that the attacker knows.
NCR SelfServ ATMs running APTRA XFS 05.01.00 do not encrypt, authenticate, or verify the integrity of messages between the BNA and the host computer, which could allow an attacker with physical access to the internal components of the ATM to execute arbitrary code, including code that enables the attacker to commit deposit forgery.