Security Vulnerabilities
- CVEs Published In June 2019
An issue was discovered in FlightCrew v0.9.2 and earlier. A NULL pointer dereference occurs in GetRelativePathToNcx() or GetRelativePathsToXhtmlDocuments() when a NULL pointer is passed to xc::XMLUri::isValidURI(). This affects third-party software (not Sigil) that uses FlightCrew as a library.
An incorrect implementation of a local web server in eID client (Windows version before 3.1.2, Linux version before 3.0.3) allows remote attackers to execute arbitrary code (.cgi, .pl, or .php) or delete arbitrary files via a crafted HTML page. This is a product from the Ministry of Interior of the Slovak Republic.
Medtronic MiniMed Insulin Pumps
are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
In WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied data. Exploitation of this vulnerability may allow disclosure of information.
In WebAccess/SCADA, Versions 8.3.5 and prior, a path traversal vulnerability is caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage this vulnerability to delete files while posing as an administrator.
In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991.
In WebAccess/SCADA, Versions 8.3.5 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
In WebAccess/SCADA Versions 8.3.5 and prior, multiple untrusted pointer dereference vulnerabilities may allow a remote attacker to execute arbitrary code.
A flaw was found in the containerized-data-importer in virt-cdi-cloner, version 1.4, where the host-assisted cloning feature does not determine whether the requesting user has permission to access the Persistent Volume Claim (PVC) in the source namespace. This could allow users to clone any PVC in the cluster into their own namespace, effectively allowing access to other user's data.