Vulnerabilities
Vulnerable Software
Security Vulnerabilities - CVEs Published In June 2017
A Padding Oracle exists in OSCI-Transport 1.2 as used in OSCI Transport Library 1.6.1 (Java) and OSCI Transport Library 1.6 (.NET). Under an MITM condition within the OSCI infrastructure, an attacker needs to send crafted protocol messages to analyse the CBC mode padding in order to decrypt the transport encryption.
CVSS Score
5.9
EPSS Score
0.001
Published
2017-06-30
Signature Wrapping exists in OSCI-Transport 1.2 as used in OSCI Transport Library 1.6.1 (Java) and OSCI Transport Library 1.6 (.NET). An attacker with access to unencrypted OSCI protocol messages must send crafted protocol messages with duplicate IDs.
CVSS Score
6.5
EPSS Score
0.001
Published
2017-06-30
An XML External Entity (XXE) issue exists in OSCI-Transport 1.2 as used in OSCI Transport Library 1.6.1 (Java) and OSCI Transport Library 1.6 (.NET), exploitable by sending a crafted standard-conforming OSCI message from within the infrastructure.
CVSS Score
9.8
EPSS Score
0.004
Published
2017-06-30
A Hard-Coded Passwords issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. The end user does not have the ability to change system passwords.
CVSS Score
9.8
EPSS Score
0.005
Published
2017-06-30
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
CVSS Score
7.5
EPSS Score
0.061
Published
2017-06-30
An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.
CVSS Score
6.1
EPSS Score
0.001
Published
2017-06-30
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.
CVSS Score
9.8
EPSS Score
0.005
Published
2017-06-30
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
CVSS Score
9.1
EPSS Score
0.148
Published
2017-06-30
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
CVSS Score
9.8
EPSS Score
0.002
Published
2017-06-30
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
CVSS Score
6.5
EPSS Score
0.004
Published
2017-06-30


Contact Us