Citrix XenApp 6.5, when 2FA is enabled, allows a remote unauthenticated attacker to ascertain whether a user exists on the server, because the 2FA error page only occurs after a valid username is entered. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
In Indy Node 1.12.2, there is an Uncontrolled Resource Consumption vulnerability. Indy Node has a bug in TAA handling code. The current primary can be crashed with a malformed transaction from a client, which leads to a view change. Repeated rapid view changes have the potential of bringing down the network. This is fixed in version 1.12.3.
An issue was discovered in janus-gateway (aka Janus WebRTC Server) through 0.10.0. janus_sdp_process in sdp.c has a NULL pointer dereference.
An issue was discovered in janus-gateway (aka Janus WebRTC Server) through 0.10.0. janus_process_incoming_request in janus.c discloses information from uninitialized stack memory.
An issue was discovered in janus-gateway (aka Janus WebRTC Server) through 0.10.0. janus_sdp_preparse in sdp.c has a NULL pointer dereference.
An issue was discovered in janus-gateway (aka Janus WebRTC Server) through 0.10.0. janus_sdp_merge in sdp.c has a stack-based buffer overflow.
Select Dell Client Consumer and Commercial platforms include an issue that allows the BIOS Admin password to be changed through Dell's manageability interface without knowledge of the current BIOS Admin password. This could potentially allow an unauthorized actor, with physical access and/or OS administrator privileges to the device, to gain privileged access to the platform and the hard drive.
Dell Client Consumer and Commercial platforms include an improper authorization vulnerability in the Dell Manageability interface for which an unauthorized actor, with local system access with OS administrator privileges, could bypass the BIOS Administrator authentication to restore BIOS Setup configuration to default values.
Mitsubishi MELSEC iQ-R Series PLCs with firmware 33 allow attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, because this denial of service attack consumes excessive CPU time. After halting, physical access to the PLC is required in order to restore production.
phpMussel from versions 1.0.0 and less than 1.6.0 has an unserialization vulnerability in PHP's phar wrapper. Uploading a specially crafted file to an affected version allows arbitrary code execution (discovered, tested, and confirmed by myself), so the risk factor should be regarded as very high. Newer phpMussel versions don't use PHP's phar wrapper, and are therefore unaffected. This has been fixed in version 1.6.0.