Security Vulnerabilities
- CVEs Published In May 2019
In PHP-Fusion 9.03.00, edit_profile.php allows remote authenticated users to execute arbitrary code because includes/dynamics/includes/form_fileinput.php and includes/classes/PHPFusion/Installer/Lib/Core.settings.inc mishandle executable files during avatar upload.
LG N1A1 NAS 3718.510 is affected by: Remote Command Execution. The impact is: execute arbitrary code (remote). The attack vector is: HTTP POST with parameters.
SAP Treasury and Risk Management (EA-FINSERV 6.0, 6.03, 6.04, 6.05, 6.06, 6.16, 6.17, 6.18 and 8.0; S4CORE 1.01, 1.02 and 1.03), does not perform necessary authorization checks for authorization objects T_DEAL_DP and T_DEAL_PD , resulting in escalation of privileges.
Under certain conditions SAP BusinessObjects Business Intelligence platform (Central Management Server), versions 4.2 and 4.3, allows an attacker to access information which would otherwise be restricted.
Under certain conditions SAP BusinessObjects Business Intelligence platform (Analysis for OLAP), versions 4.2 and 4.3, allows an attacker to access information which would otherwise be restricted.
Under certain conditions Solution Manager, version 7.2, allows an attacker to access information which would otherwise be restricted.
Read of RFC destination does not always perform necessary authorization checks, resulting in escalation of privileges to access information on RFC destinations on managed systems and SAP Solution Manager system (ST-PI, before versions 2008_1_700, 2008_1_710, and 740).
SAP E-Commerce (Business-to-Consumer) application does not sufficiently encode user-controlled inputs, resulting in Cross-Site Scripting (XSS) vulnerability. Fixed in the following components SAP-CRMJAV SAP-CRMWEB SAP-SHRWEB SAP-SHRJAV SAP-CRMAPP SAP-SHRAPP, versions 7.30, 7.31, 7.32, 7.33, 7.54.
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.