Security Vulnerabilities
- CVEs Published In March 2021
Cross-site Scripting (XSS) vulnerability in MyBB before 1.8.26 via Nested Auto URL when parsing messages.
This affects all versions of package ps-kill. If (attacker-controlled) user input is given to the kill function, it is possible for an attacker to execute arbitrary commands. This is due to use of the child_process exec function without input sanitization in the index.js file. PoC (provided by reporter): var ps_kill = require('ps-kill'); ps_kill.kill('$(touch success)',function(){});
This affects all versions of package kill-process-by-name. If (attacker-controlled) user input is given, it is possible for an attacker to execute arbitrary commands. This is due to use of the child_process exec function without input sanitization in the index.js file.
All versions of package github.com/tyktechnologies/tyk/gateway are vulnerable to Directory Traversal via the handleAddOrUpdateApi function. This function is able to delete arbitrary JSON files on the disk where Tyk is running via the management API. The APIID is provided by the user and this value is then used to create a file on disk. If there is a file found with the same name then it will be deleted and then re-created with the contents of the API creation request.
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
A vulnerability has been identified in Mendix Forgot Password Appstore module (All Versions < V3.2.1). The Forgot Password Marketplace module does not properly control access. An attacker could take over accounts.
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service.
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a NULL pointer deference condition could cause the application to terminate unexpectedly and must be restarted to restore the service.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.
A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). The underlying TCP stack of the affected products does not correctly validate the sequence number for incoming TCP RST packages. An attacker could exploit this to terminate arbitrary TCP sessions.