Security Vulnerabilities
- CVEs Published In March 2019
A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible.
Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless capacity in a clinical setting. Hospira has developed a new version of the PCS Infusion System, version 7.0 that addresses the identified vulnerabilities. Version 7.0 has Port 20/FTP and Port 23/TELNET closed by default to prevent unauthorized access.
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.
A Reflected Cross Site Scripting (XSS) Vulnerability was discovered in Adrenalin 5.4 HRMS Software. The user supplied input containing JavaScript is echoed back in JavaScript code in an HTML response via the LeaveEmployeeSearch.aspx prntFrmName or prntDDLCntrlName parameter.
A Reflected Cross Site Scripting (XSS) vulnerability exists in Adrenalin HRMS 5.4.0. An attacker can input malicious JavaScript code in /RPT/SSRSDynamicEditReports.aspx via 'ReportId' parameter.
A flaw was found in libssh2 before 1.8.1 creating a vulnerability on the SSH client side. A server could send a multiple keyboard interactive response messages whose total length are greater than unsigned char max characters. This value is used by the SSH client as an index to copy memory causing in an out of bounds memory write error.
Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior accept drug libraries, firmware updates, pump commands, and unauthorized configuration changes from unauthenticated devices on the host network. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.
In ovirt-engine 4.1, if a host was provisioned with cloud-init, the root password could be revealed through the REST interface.
A flaw was found in sssd Group Policy Objects implementation. When the GPO is not readable by SSSD due to a too strict permission settings on the server side, SSSD will allow all authenticated users to login instead of denying access.
It was found that libreoffice before versions 6.0.7 and 6.1.3 was vulnerable to a directory traversal attack which could be used to execute arbitrary macros bundled with a document. An attacker could craft a document, which when opened by LibreOffice, would execute a Python method from a script in any arbitrary file system location, specified relative to the LibreOffice install location.