Vulnerabilities
Vulnerable Software
Security Vulnerabilities - CVEs Published In March 2019
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
CVSS Score
7.5
EPSS Score
0.0
Published
2019-03-26
Hospira MedNet software version 5.8 and prior uses vulnerable versions of the JBoss Enterprise Application Platform software that may allow unauthenticated users to execute arbitrary code on the target system. Hospira has developed a new version of the MedNet software, MedNet 6.1. Existing versions of MedNet can be upgraded to MedNet 6.1.
CVSS Score
9.8
EPSS Score
0.017
Published
2019-03-26
CentOS-WebPanel.com (aka CWP) CentOS Web Panel through 0.9.8.763 is vulnerable to Stored/Persistent XSS for the "Package Name" field via the add_package module parameter.
CVSS Score
4.8
EPSS Score
0.005
Published
2019-03-26
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes.
CVSS Score
6.8
EPSS Score
0.001
Published
2019-03-26
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
CVSS Score
9.8
EPSS Score
0.008
Published
2019-03-26
An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
CVSS Score
9.8
EPSS Score
0.003
Published
2019-03-26
GitLab CE/EE before 11.3.12, 11.4.x before 11.4.10, and 11.5.x before 11.5.3 allows Directory Traversal in Templates API.
CVSS Score
7.5
EPSS Score
0.001
Published
2019-03-26
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
CVSS Score
9.8
EPSS Score
0.002
Published
2019-03-26
Flatpak before 1.0.8, 1.1.x and 1.2.x before 1.2.4, and 1.3.x before 1.3.1 allows a sandbox bypass. Flatpak versions since 0.8.1 address CVE-2017-5226 by using a seccomp filter to prevent sandboxed apps from using the TIOCSTI ioctl, which could otherwise be used to inject commands into the controlling terminal so that they would be executed outside the sandbox after the sandboxed app exits. This fix was incomplete: on 64-bit platforms, the seccomp filter could be bypassed by an ioctl request number that has TIOCSTI in its 32 least significant bits and an arbitrary nonzero value in its 32 most significant bits, which the Linux kernel would treat as equivalent to TIOCSTI.
CVSS Score
9.0
EPSS Score
0.001
Published
2019-03-26
HashiCorp Consul 1.4.3 lacks server hostname verification for agent-to-agent TLS communication. In other words, the product behaves as if verify_server_hostname were set to false, even when it is actually set to true. This is fixed in 1.4.4.
CVSS Score
7.4
EPSS Score
0.002
Published
2019-03-26


Contact Us