Vulnerabilities
Vulnerable Software
Security Vulnerabilities - CVEs Published In March 2019
An issue was discovered on PHOENIX CONTACT RAD-80211-XD and RAD-80211-XD/HP-BUS devices. Command injection can occur in the WebHMI component.
CVSS Score
8.8
EPSS Score
0.026
Published
2019-03-26
An issue was discovered on PHOENIX CONTACT FL NAT SMCS 8TX, FL NAT SMN 8TX, FL NAT SMN 8TX-M, and FL NAT SMN 8TX-M-DMG devices. There is unauthorized access to the WEB-UI by attackers arriving from the same source IP address as an authenticated user, because this IP address is used as a session identifier.
CVSS Score
8.8
EPSS Score
0.004
Published
2019-03-26
A cross-site scripting (XSS) vulnerability in ressource view in core/modules/resource/RESOURCEVIEW.php in Wikindx prior to version 5.7.0 allows remote attackers to inject arbitrary web script or HTML via the id parameter.
CVSS Score
6.1
EPSS Score
0.002
Published
2019-03-26
In Drupal 7 versions prior to 7.65; Drupal 8.6 versions prior to 8.6.13;Drupal 8.5 versions prior to 8.5.14. Under certain circumstances the File module/subsystem allows a malicious user to upload a file that can trigger a cross-site scripting (XSS) vulnerability.
CVSS Score
5.4
EPSS Score
0.546
Published
2019-03-26
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.
CVSS Score
6.5
EPSS Score
0.0
Published
2019-03-26
The application server component of TIBCO Software Inc.'s TIBCO Data Science for AWS, and TIBCO Spotfire Data Science contains a persistent cross-site scripting vulnerability that theoretically allows an authenticated user to gain access to all the capabilities of the web interface available to more privileged users. Affected releases are TIBCO Software Inc.'s TIBCO Data Science for AWS: versions up to and including 6.4.0, and TIBCO Spotfire Data Science: versions up to and including 6.4.0.
CVSS Score
7.6
EPSS Score
0.004
Published
2019-03-26
The application server component of TIBCO Software Inc.'s TIBCO Data Science for AWS, and TIBCO Spotfire Data Science contains a persistent cross-site contains a vulnerability that theoretically allows a user to escalate their privileges on the affected system, in a way that may allow for data modifications and deletions that should be denied. Affected releases are TIBCO Software Inc.'s TIBCO Data Science for AWS: versions up to and including 6.4.0, and TIBCO Spotfire Data Science: versions up to and including 6.4.0.
CVSS Score
6.5
EPSS Score
0.004
Published
2019-03-26
The application server component of TIBCO Software Inc.'s TIBCO Data Science for AWS, and TIBCO Spotfire Data Science contains a vulnerability that theoretically enables a user to spoof their account to look like a different user in the affected system. Affected releases are TIBCO Software Inc.'s TIBCO Data Science for AWS: versions up to and including 6.4.0, and TIBCO Spotfire Data Science: versions up to and including 6.4.0.
CVSS Score
5.0
EPSS Score
0.002
Published
2019-03-26
The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services.
CVSS Score
9.8
EPSS Score
0.014
Published
2019-03-26
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
CVSS Score
7.5
EPSS Score
0.0
Published
2019-03-26


Contact Us

Shodan ® - All rights reserved