SunGrow WiNet-S V200.001.00.P025 and earlier versions is missing integrity checks for firmware upgrades. Sending a specific MQTT message allows an update to an inverter or a WiNet connectivity dongle with a bogus firmware file that is located on attacker-controlled server.
A vulnerability in the web UI of Cisco APIC could allow an authenticated, remote attacker to perform a stored XSS attack on an affected system. To exploit this vulnerability, the attacker must have valid administrative credentials.
This vulnerability is due to improper input validation in the web UI. An authenticated attacker could exploit this vulnerability by injecting malicious code into specific pages of the web UI. A successful exploit could allow the attacker to execute arbitrary script code in the context of the web UI or access sensitive, browser-based information.
A vulnerability in the CLI of Cisco APIC could allow an authenticated, local attacker to execute arbitrary commands as root on the underlying operating system of an affected device. To exploit this vulnerability, the attacker must have valid administrative credentials.
This vulnerability is due to insufficient validation of arguments that are passed to specific CLI commands. An attacker could exploit this vulnerability by including crafted input as the argument of an affected CLI command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with the privileges of root.
A vulnerability in the implementation of the internal system processes of Cisco APIC could allow an authenticated, local attacker to access sensitive information on an affected device. To exploit this vulnerability, the attacker must have valid administrative credentials.
This vulnerability is due to insufficient masking of sensitive information that is displayed through system CLI commands. An attacker could exploit this vulnerability by using reconnaissance techniques at the device CLI. A successful exploit could allow the attacker to access sensitive information on an affected device that could be used for additional attacks.
A vulnerability in the system file permission handling of Cisco APIC could allow an authenticated, local attacker to overwrite critical system files, which could cause a DoS condition. To exploit this vulnerability, the attacker must have valid administrative credentials.
This vulnerability is due to a race condition with handling system files. An attacker could exploit this vulnerability by doing specific operations on the file system. A successful exploit could allow the attacker to overwrite system files, which could lead to the device being in an inconsistent state and cause a DoS condition.
decNumberCopy in decNumber.c in jq through 1.7.1 does not properly consider that NaN is interpreted as numeric, which has a resultant stack-based buffer overflow and out-of-bounds write, as demonstrated by use of --slurp with subtraction, such as a filter of .-. when the input has a certain form of digit string with NaN (e.g., "1 NaN123" immediately followed by many more digits).
A SQL Injection vulnerability was found in /admin/add-propertytype.php in PHPGurukul Land Record System Project in PHP v1.0 allows remote attackers to execute arbitrary code via the propertytype POST request parameter.
A stored cross site scripting (XSS) vulnerability in HelpDeskZ < v2.0.2 allows remote attackers to execute arbitrary JavaScript in the administration panel by including a malicious payload into the file name and upload file function when creating a new ticket.
SeaCMS v13.3 was discovered to contain a remote code execution (RCE) vulnerability via the component admin_ip.php.
SeaCMS v13.3 was discovered to contain a remote code execution (RCE) vulnerability via the component admin_files.php.