Vulnerabilities
Vulnerable Software
Security Vulnerabilities - CVEs Published In January 2022
CVE-2021-40407
Known exploited
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->domain variable, that has the value of the domain parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection. An attacker can send an HTTP request to trigger this vulnerability.
CVSS Score
9.1
EPSS Score
0.473
Published
2022-01-28
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->username variable, that has the value of the userName parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection.
CVSS Score
9.1
EPSS Score
0.054
Published
2022-01-28
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->password variable, that has the value of the password parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection.
CVSS Score
9.1
EPSS Score
0.054
Published
2022-01-28
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [4] the dns_data->dns1 variable, that has the value of the dns1 parameter provided through the SetLocal API, is not validated properly. This would lead to an OS command injection.
CVSS Score
9.1
EPSS Score
0.048
Published
2022-01-28
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [6] the dns_data->dns2 variable, that has the value of the dns2 parameter provided through the SetLocalLink API, is not validated properly. This would lead to an OS command injection.
CVSS Score
9.1
EPSS Score
0.039
Published
2022-01-28
An OScommand injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [8] the devname variable, that has the value of the name parameter provided through the SetDevName API, is not validated properly. This would lead to an OS command injection.
CVSS Score
9.1
EPSS Score
0.048
Published
2022-01-28
An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. The UpgradePrepare is the API that checks if a provided filename identifies a new version of the RLC-410W firmware. If the version is new, it would be possible, allegedly, to later on perform the Upgrade. An attacker can send an HTTP request to trigger this vulnerability.
CVSS Score
7.1
EPSS Score
0.002
Published
2022-01-28
An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. The SetMdAlarm API sets the movement detection parameters, giving the ability to set the sensitivity of the camera per a range of hours, and which of the camera spaces to ignore when considering movement detection. Because in cgi_check_ability the SetMdAlarm API does not have a specific case, the user permission will default to 7. This will give non-administrative users the possibility to change the movement detection parameters.
CVSS Score
7.1
EPSS Score
0.002
Published
2022-01-28
An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. In cgi_check_ability the Format API does not have a specific case, the user permission will default to 7. This will give non-administrative users the possibility to format the SD card and reboot the device.
CVSS Score
7.1
EPSS Score
0.003
Published
2022-01-28
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
CVSS Score
6.1
EPSS Score
0.008
Published
2022-01-28


Contact Us

Shodan ® - All rights reserved